Load Match, Insertion Loss And Isolation Test For Switch 1 (Sp4T, Port 1, 1A, 1B, 1C And 1D) - Agilent Technologies ENA Series Service Manual

Configurable multiport test set
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Performance Tests
E5092A Performance Test Record
Load Match, Insertion Loss and Isolation Test for Switch 1 (SP4T, Port
1, 1A, 1B, 1C and 1D)
Load Match (Unselected)
Port
Frequency
(Selected
Range [Hz]
Port)
1B (1A)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
1C (1A)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
1D (1A)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
1A (1B)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
1C (1B)
50M to 3G
3G to 10G
10G to 16G
16G to 18G
18G to 20G
46
Test Limit
Test Result [dB]
[dB]
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
< -17.0
< -11.0
< -8.0
< -6.0
< -4.0
Measurement
Uncertainty
[dB]
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
± 0.43
± 0.37
± 0.28
± 0.28
± 0.35
Chapter 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5092a

Table of Contents