84/96 Bosch Rexroth AG
Maintenance and repair
9.2

Maintenance

Testing the residual-current-operated
protective device
The residual-current-operated
protective device is only available
with the CS351E Compact System
for ErgoSpin hand-held nutrunners.
Check the function of the residual-current-
operated protective device (RCD) by actuating
the test button. Unless otherwise specified, we
recommend performing this test once a month,
but at least every six months.
If the residual-current-operated protective
device has been triggered, the control voltage for
the power and controller electronics will be
maintained. Only the main circuit will be isolated.
NOTE
Damages to the compact system
Do not press the test button while
tightening.
If the residual-current-operated protective
device has been triggered, only switch it on
again after tightening has been completed
(abort by the controller).
1. Actuate the test button. The residual-
current-operated protective device must
be triggered (position "0").
2. Switch the residual-current-operated
protective device back on (position "1").
CS351/CC-CS351 | 3 609 929 B45/2019-12
1
Fig. 31:
Testing the residual-current-operated
protective device
1 Test button for the residual-current-operated
protective device
Spare parts and accessories
For the addresses of out national
representations, please refer to
www.boschrexroth.com and to the address
directory in chapter "12 Disposal" on page 86.
Accessories
Tab.20: Accessories
Accessories
USB350 programming cable
US power supply connection
cable CS351USC (110 V)
CF350
CF350 1GB
Part no.
3 608 877 427
3 608 877 033
3 608 877 428
0 608 830 318

Hide quick links: