en | Routine maintenance inspection
7

Routine maintenance inspection

In order to check correct operation in case of potential cabling failure, simulate faults and
observe system reaction. Perform following procedure:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Refer to
2021.07.28 | V1.00 |
Check if LDB is powered.
If LDB is indicating FAULT mode (orange LED blinking), see PRA-LID (LDB), page 22 .
IMPORTANT: Continue to next steps only if LDB is indicating QUIESCENT mode.
Put LDB into SERVICE mode (press SERVICE button for 10 seconds).
Simulate short-circuit fault.
Using a jumper make direct short between L+ and L- wire on PRIMARY or
SECONDARY output of LDB.
Confirm that SHORT indication on LDB appears.
Confirm that fault contact was activated.
Remove the short circuit. Confirm that SHORT indication on LDB disappears.
Simulate open loop fault
Disconnect loop cable from PRIMARY or SECONDARY output of LDB.
Confirm that OPEN indication on LDB appears.
Confirm that fault contact was activated.
Connect the loop cable back to LDB. Confirm that OPEN indication on LDB
disappears.
Put LDB into QUIESCENT mode.
Simulate earth leakage fault:
Make direct connection between L+ or L- wire to ground potential (Ground pin of
LDB)
Confirm that EARTH indication on LDB appears.
Confirm that fault contact was activated.
Remove the connection between L+ or L- to earth.
Confirm that EARTH "active" (fast) indication on LDB turns into "memory" (slow).
Reset LDB into QUIESCENT mode.
Simulate ground wire open fault (optional)
Open ground wire on PRIMARY or SECONDARY output of LDB.
Confirm that EARTH indication on LDB appears.
Confirm that fault contact was activated.
Connect ground wire back to LDB.
Confirm that EARTH "active" (fast) indication on LDB turns into "memory" (slow).
Reset LDB into QUIESCENT mode.
Check cables and connectors between LDB and Public Address / Voice Alarm system.
PRA-LID (LDB), page 22
Installation manual