80/96 Bosch Rexroth AG

Maintenance and repair

Maintenance and repair
9
DANGER
Electrical voltages!
Electrocution
Do not carry out maintenance work on the
tightening channel unless the Compact
System has been switched off and the
power plug disconnected. Protect the
system from being switched on again.
9.1

Repair

Reset function of the Compact System
Fig. 27:
Reset button
A software reset is generated if the reset button
is briefly pressed, i.e. for < 1 second. The
controller is reset once the button is released.
A hardware reset is generated if the reset button
is pressed for a long period, i.e. for > 3 seconds.
The controller and servo amplifier are reset once
the button is released.
CS351/CC-CS351 | 3 609 929 B45/2019-12
Exchanging fuses
DANGER
Electrical voltages!
Electrocution
Do not carry out maintenance work on the
tightening channel unless the Compact
System has been switched off and the
power plug disconnected. Protect the
system from being switched on again.
Wait until the discharging time (at least 90
seconds) has elapsed.
• Open and remove the front cover.
• Remove the four bolts on the front plate and
take off the front plate.
• Exchange the fuses (see Fig.28).