Installation Of The Product - Gardena SILENO city Operator's Manual

Hide thumbs Also See for SILENO city:
Table of Contents

Advertisement

3.4.5 Work area examples
If the charging station is put in a small area (A),
make sure that the distance to the boundary wire is
at a minimum 2 m / 6.6 ft. in front of the charging
station.
If the work area has a passage (B) with no guide
wire installed, the minimum distance between the
boundary wires is 2 m / 6.5 ft. With a guide wire
installed through the passage, the minimum
distance between the boundary wires is 60 cm / 24
CorridorCut function to cut this
in. Use the
passage, Refer to
Lawn Coverage and CorridorCut
on page 25 .
If the work area has areas which are connected by
a narrow passage (B), you can set the product to
first follow and then leave the guide wire after a
certain distance (C). The settings can be changed
Lawn Coverage and CorridorCut on page 25 .
in
If the work area includes a secondary area (D),
refer to
Secondary area on page 31 . Put the
product in the secondary area and select
Secondary area mode .
D
B

3.5 Installation of the product

3.5.1 Installation tools
Hammer/plastic mallet: To simplify putting the
stakes into the ground.
Edge cutter/straight spade: To bury the boundary
wire.
1298 - 007 - 16.09.2020
Combination pliers: For cutting the boundary wire
and pressing the connectors together.
Adjustable plier: For pressing the couplers
together.
3.5.2 To install the charging station
A
C
When connecting the power supply, only use a power
outlet that is connected to an residual-current device
(RCD).
WARNING:
Obey national regulations
about electrical safety.
WARNING:
The product is only to be
used with the power supply unit supplied by
GARDENA.
WARNING:
Do not put the power
supply at a height where there is a risk it can
be put in water. Do not put the power supply
on the ground.
WARNING:
Do not encapsulate the
power supply. Condensed water can harm
the power supply and increase the risk of
electrical shock.
WARNING:
Risk of Electric Shock.
Install only to an residual-current device
(RCD) when connecting the power supply to
the power outlet. Applicable to USA/Canada.
If power supply is installed outdoors: Risk of
Electric Shock. Install only to a covered
Class A GFCI receptacle (RCD) that has an
enclosure that is weatherproof with the
attachment plug cap inserted or removed.
CAUTION:
Do not make new holes in
the charging station plate.
CAUTION:
Do not put your feet on the
baseplate of the charging station.
WARNING:
The power supply cable
and extension cable must be outside the
work area to avoid damage to the cables.
Installation - 19