Gardena SILENO city Operator's Manual page 46

Hide thumbs Also See for SILENO city:
Table of Contents

Advertisement

2.
Check that the boundary wire connections to the
charging station are properly connected and not
damaged. Check that the indicator lamp in the
charging station is still flashing blue.
GUIDE
R
3.
Switch the connections between the guide wire
and the boundary wire in the charging station.
Start by switching connection L and GUIDE.
If the indicator lamp is flashing yellow, then the
break is somewhere on the boundary wire between
L and the point where the guide wire is connected
to the boundary wire (thick black line in the
illustration).
46 - Troubleshooting
L
POWER
GUIDE
Guide
To rectify the fault you will need boundary wire,
connector(s) and coupler(s):
a) If the suspected boundary wire is short then it is
easiest to exchange all of the boundary wire
between L and the point where the guide wire is
connected to the boundary wire (thick black line).
b) If the suspected boundary wire is long (thick
black line) then do as follows: Put L and GUIDE
back to their original positions. Then disconnect R.
Connect a new loop wire to R. Connect the other
end of this new loop wire at the middle of the
suspected wire section.
1298 - 007 - 16.09.2020
L