3.4.5 Work area examples
If the charging station is put in a small area
(A), make sure that the distance to the
boundary wire is at a minimum 3 m / 10 ft. in
front of the charging station.
If the work area has a passage (B) with no
guide wire installed, the minimum distance
between the boundary wires is 2 m / 6.5 ft.
With a guide wire installed through the
passage, the minimum distance between the
boundary wires is 60 cm / 24 in.
If the work area has areas which are
connected by a narrow passage (B), you
can set the product to first follow and then
leave the guide wire after a certain distance
(C). The settings can be changed in
Coverage on page 25 .
If the work area includes a secondary area
To make a secondary area on
(D), refer to
page 18 . Put the product in the secondary
Secondary area mode .
area and select
1378 - 003 - 16.04.2020

3.5 Installation of the product

Lawn
3.5.1 Installation tools
Hammer/plastic mallet: To simplify putting
the stakes into the ground.
Edge cutter/straight spade: To bury the
boundary wire.
Combination pliers: For cutting the boundary
wire and pressing the connectors together.
Adjustable plier: For pressing the couplers
together.
3.5.2 To install the charging station
WARNING: Obey national regulations
about electrical safety.
WARNING: The product is only to be
used with the power supply unit
supplied by GARDENA.
D
A
B
C
Installation - 19