ABB Terra DC Wallbox Installation Manual page 29

Hide thumbs Also See for Terra DC Wallbox:
Table of Contents

Advertisement

2. Push the cables back through the gland plate, until sufficient cable length is left to reach the cable termi-
nals. Ensure the PE cable is longer than the other cables.
3. Tighten the strain relief.
4. Slide the cable cover and tighten the two screws.
If a wired internet connection is not used, please ensure the cable entry hole is closed, to assure the IP54
grade of the cabinet, and prevent insects and small animals to enter the cabinet.
NOTE 1: A ferrite core (3-phase and 1-phase versions) is provided with the Wallbox (plastic bag within the
package or strapped to the CCS-1 cable) and needs to be installed in commissioning phase. The Ferrite needs
2 0 2 0- 0 8- 0 6
TER R A DC WAL LB OX
208/240V 1-phase version
Wire pass thru locations
Conduit
Installation 1.25"
secured to bottom
mounting area.
1-phase Version
Shown
2 9 / 41