Cleaning
Fill level indicator
If needed, the fill level indicator (a) may be cleaned from the inside using the right
bottle brush.
1. Undo the screw (d) at the top next to the
fill level indicator support.
2. Remove the glass pipe (b) and the top
gasket (c).
3. Introduce the bottle brush into the glass
pipe (b) and clean it thoroughly, using
warm water and a gentle washing agent.
4. Rinse thoroughly with clear water.
5. Then fit the fill level indicator onto the
support. Pay attention at the right position
of gaskets (c) at the bottom and at the
top.
ATTENTION!
Pay attention if the glass pipe is correctly positioned in the gasket.
Tighten the screw union gently, as the glass pipe may be broken.
6. Tighten the fill level indicator screw (d).
6.3

Descaling

Depending on the water hardness level in the place of usage, limescale may be
deposited in the water tank and the heating bowl during the operation of the coffee
machine. In order to maintain the appliance in the best possible condition, and in
order to be certain that every brewing process yields the best results, the appliance
should be descaled regularly.
The appliance is equipped with red malfunction indicator. Depending on the
hardness of the water used, the indicator may be activated after a certain number of
brewing cycles, which indicates that the appliance must be descaled. The
thermostat is activated and thus it stops the operation of the appliance.
NOTE!
To reduce limescale deposits, it is recommended to use filtered water!