FE6600/BL6600/MP6600 Series Multi-point Lock
Installation Instructions
4
Regulatory Specifi cations
Electrical Specifi cations
12/24VDC System
• Reader Draw = 200mA (Peak; average = 81mA @12VDC)
• Actuator Draw =15mA continuous (500mA peak)
The reader requires 12VDC for power, while the lock accepts either 12
or 24VDC.
UL and CUL listed for use on Fire Doors
Wire Gauge Charts
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2017, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Total
One-Way
Length of
Wire Run
1/4A
1/2A
3/4A
(ft)
100
20
18
16
150
18
16
14
200
16
14
12
250
16
14
12
300
16
12
12
400
14
12
10
500
14
10
10
750
12
10
1,000
10
1,500
10
Total
One-Way
Length of
Wire Run
1/4A
1/2A
3/4A
(ft)
100
24
20
18
150
22
18
16
200
20
18
16
250
18
16
14
300
18
16
14
400
18
14
12
500
16
14
12
750
14
12
10
1,000
14
10
10
1,500
12
10
McKinney
Electric
Load Current @ 12VDC
1A
1-1/4A
1-1/2A
2A
3A
14
14
12
12
10
12
12
12
10
12
10
10
10
10
10
10
10
Load Current @ 24VDC
1A
1-1/4A
1-1/2A
2A
18
16
16
14
16
14
14
12
14
14
12
12
14
12
12
12
12
12
12
10
12
10
10
10
10
10
5
Wiegand Access
Control System
Hinge
SE LP10
3A
12
10
10
10
FM456 08/20

Advertisement

Table of Contents
loading

Table of Contents