Setting Up / Fastening / Mounting The Filter Housing; Hydraulically Connecting The Filter Housing - HYDAC FILTER SYSTEMS MRF4 Installation And Maintenance Instructions Manual

Multirheo filter
Table of Contents

Advertisement

Setting up / fastening / mounting the filter housing

Place the filter housing on a flat horizontal surface that has a sufficient load-
carrying capacity and resilience.
Make sure to leave sufficient room, at least 1 m, over the filter housing to
change the filter element.
Fasten the filter housing with suitable floor anchors.

Hydraulically connecting the filter housing

Connect the filter housing hydraulically using a flexible hose connection or
pipeline.
Make sure that no vibrations and/or stress from other machinery and
equipment are carried over to filter housing. Use expansion joints if
necessary.
MRF4
MoWa MRF4 3214670d en-us 2018-02-09.docx
Setting up / fastening / mounting the filter housing
en(us)