Adjusting the Curtain Offset
The curtain opening offset is the number of degrees above the set point at
which the thermostat controller starts opening the curtain continuously;
the SMART THERMOSTAT disables the curtain's closing relay while it opens
the curtain.
The offset can be adjusted between 0.5
The temperature at which the SMART THERMOSTAT starts
opening the actuator (set point + curtain open offset) should be
set to a higher temperature value than the highest opening step
of the same air intake in the main controller. This way, SMART
THERMOSTAT will not influence the operation of the air intake
during regular ventilation stages, it will only open the air intake if
the temperature increases abnormally due to a failure of the main
controller.
Set the function to CURTAIN OPEN OFFSET using the function selec-
tor buttons. The current curtain offset is displayed, alternating with
the letters "OFT".
Use the adjustment buttons to adjust the offset to the desired value.
26
SMART THERMOSTAT rev.01
F and 40.0
F (0.3
o
o
C and 22.2
C).
o
o