5.14

MV/ZONE

This feature allows you to select which master valve(s) to be
assigned for each zone operation. The default is MV1. The other
options are MV2, BOTH, OFF.
Caution: If an unused zone is turned on and activates a pump
start relay, the pump may overheat or cause a pipe to burst. To
prevent operating a pump with no flow (dead heading), make
sure all unused zones are set to OFF.
5.15

MV/ZN DLY

This function allows the user to set a delay time between the
opening of the master valve and the opening of the first zone
valve as well as a delay between the closing of the last zone
valve and the closing of the master valve.
Use the NEXT button to enter menu. Select setting for the ON
Delay or OFF Delay by pressing NEXT. Use UP and DOWN
buttons to select delay time. Use UP and DOWN buttons to
set ON Delay time from 0 seconds to 1 minute in 1 second
increments. OFF Delay can be set from 0 seconds to 3 minutes
in 1 second increments.
5.16

MV2 ZONE

A second master valve circuit can be enabled in this menu by
designating a zone valve to be MV2
5.17

ZN/ZN DLY

This function allows user to set delay times between zone starts
for use in systems with slow closing valves or pump systems that
are operating near maximum flow or have slow well recovery.
Use UP and DOWN buttons to change value. Adjustable in one-
5.0 Advanced Menu
minute increments from 0 (the SmartLine® controller default
setting) to 30 minutes; adjustable in 10 minute increments from
30 minutes to 3 hours.
5.18

NUM START

This SmartLine® feature allows you to select the number of
Watering Program Start Times that you want to appear at
Program Start Times on the dial. The default number of start
times shown is 3. To select 1 to 8 start times, go to Advanced
Functions, NUM STRT. Press Next to view the default of 3 start
times. Scroll the UP/DOWN buttons to select 1 to 8 start times
to be visible on the dial. Return the dial to Run.
5.19

DS TIME

Your SmartLine® controller can automatically adjust the time for
daylight saving time (DST). The factory default setting is OFF
and has been preset for the current USA schedule. To turn DST
adjust ON, press the next button at DS TIME, the NEXT button at
ON/OFF then select ON.
The DS Time feature can be customized to match any
international DST schedule. Press the NEXT button at DS
TIME in advanced functions. Select DS SETUP and press the
NEXT button again. You will be prompted to enter the START
schedule (time of day is moved ahead 1 hour per START
schedule), and the STOP schedule (time of day is moved back
1 hour per STOP schedule). DST start and stop are formatted
with the the Week (first, second, third, last), the Day (Sun-Sat)
and the Month (Jan-Dec). All DS Time adjustments are made at
2 am. To return the DS Time schedule back to the USA factory
default, use the US DEFLT option.