5.0 Advanced Menu
14
SCROLLING FAULT
MESSAGE
ZONE XX SHORT
OUTPUT SHORT CIRCUIT: A load placed
on any output that results in a current draw
MV1 SHORT
exceeding the skip current setting will
result in a fault after the output is turned
MV2 SHORT
on. The output will be skipped until the
next watering program attempts to use
it. If the MV/P output is shorted, all zones
using it will effectively be skipped. The
fault indication can be manually cleared or
will be automatically cleared if the short
condition goes away and the output turns on
successfully.
ZONE XX OPEN
OUTPUT OPEN CIRCUIT: If a zone has a
current draw less than 0.03 Amps a zone
MV1 OPEN
open fault is created, but operation continues
normally. The fault can be manually cleared
MV2 OPEN
or will automatically clear if a load exceeding
25 mA is placed on the output and the output
turns on successfully.
NO RECENT
COMMUNICATIONS FAILURE: If the
CONTACT
SmartLine® controller is in SMART mode and
WITH Weather
the daily high/low temperature has not been
Sensor
received by midnight, this communication
fault is set. Also, if the battery in the SLW
Weather Sensor is dead, the communication
fault is set. If up to 5 days pass without
communication, the controller will revert to
the BASIC mode Zone Run Times. The fault
indication can be manually cleared or will
clear automatically once communication is
received.
http://support.weathermatic.com
FAULT DESCRIPTION
SCROLLING FAULT
MESSAGE
REMOTE
If the SmartLine® controller receives commu-
BATTERY
nication from the SLW Weather Sensor that
FAILURE
indicates the remote battery is low, the fault
is set. The fault indication can be manually
cleared or will clear automatically if the SLW
Weather Sensor sends another message that
indicates a good battery. The fault will also
clear if no communication is received for a full
day (i.e. communication failure). See Section
6.3 Replacing SLW Series Weather Sensor
Battery.
ZONE XX
INSUFFICIENT WATERING OPPORTUNITY: If
INSUFFICIENT
the SmartLine® controller is in SMART mode,
WATERING
and a daily deficit is calculated that results in
OPPORTUNITY
a zone watering deficit in excess of the 1.5"
maximum, the deficit is capped to the max-
imum and the fault is set. The fault will clear
automatically if the deficit drops below 1.5 or
can be cleared manually.

5.3 OPEN CIRCUIT FAULT

This is a user selectable feature that sends a fault message for
zones that detect no electrical load. From the ADVANCED MENU
dial position press the UP button until the "OPEN FLT" menu is
displayed. Press the NEXT button to enter the menu and the UP
or DOWN buttons to select on or off for the alert.

5.4 LANGUAGE

English, Espanol (Spanish), Italiano (Italian), Portuguese, or
Francais (French) may be selected.