Y-Axis Calibration - Bresser T-REX 2 Quick Start Manual

Hide thumbs Also See for T-REX 2:
Table of Contents

Advertisement

Y-axis calibration is used to adjust the consistency of the two extruders in the Y-axis
direction to prevent misalignment during printing.
1. Tap [Setting]-[Y Calibration], or continue the Y-axis calibration after the X-axis
calibration is completed. After the machine initialization movement is completed,
the nozzle and the platform will be heated. At this time, please ensure that the
filament has been inserted into the extruder.
2. After heating, left and right extruders print a line one by one.
3. According to the actual printed lines, click Y-, Y + to adjust the bias of the
extruders and remove the printed lines; tap the verify button, the left and right
extruders will print the lines again to see if the lines coincide, if they coincide, it
means that the Y-axis calibration is completed, if they are inconsistent, continue
to adjust, until it coincides.

Y-axis calibration

- 14 -