Version
Connection tube
Sensor material PVDF
Sensor protection PE
Flange GFK/seal ledge PVDF
Process pressure
Permissible process pressure
Mechanical stress
5)
Vibration resistance
Ʋ Suspension cable
Ʋ Connection tube
Shock resistance
Electromechanical data - version IP66/IP67 and IP66/IP68 (0.2 bar)
Options of the cable entry
Ʋ Cable entry
Ʋ Cable gland
Ʋ Blind plug
Ʋ Closing cap
Material cable gland/Seal insert
PA/NBR
Brass, nickel-plated/NBR
Stainless steel/NBR
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Depending on the instrument version
5)
2 g with housing version stainless steel double chamber
6)
IP66/IP68 (0.2 bar), only with absolute pressure.
7)
VEGABAR 86 • Foundation Fieldbus
Measuring cell seal
FKM (VP2/A)
EPDM (A+P 70.10-02)
FFKM (Kalrez 6375)
FKM (VP2/A)
EPDM (A+P 70.10-02)
FFKM (Kalrez 6375)
FKM (VP2/A)
EPDM (A+P 70.10-02)
FKM (VP2/A)
EPDM (A+P 70.10-02)
FFKM (Kalrez 6375)
see specification "Process pressure" on the type label
4 g at 5 ... 200 Hz according to EN 60068-2-6 (vibration
with resonance)
1 g (with lengths > 0.5 m (1.64 ft), the tube must be sup-
ported in addition)
50 g, 2.3 ms according to EN 60068-2-27 (mechanical
shock)
6)
M20 x 1.5; ½ NPT
M20 x 1.5, ½ NPT (cable ø see below table)
M20 x 1.5; ½ NPT
½ NPT
5 ... 9 mm
6 ... 12 mm
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Process temperature
-20 ... +100 °C (-4 ... +212 °F)
-10 ... +100 °C (+14 ... +212 °F)
-20 ... +60 °C (-4 ... +140 °F)
-10 ... +60 °C (+14 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
-20 ... +80 °C (-4 ... +176 °F)
-10 ... +80 °C (+14 ... +176 °F)
7)
Cable diameter
7 ... 12 mm
11 Supplement
10 ... 14 mm
61