PVI 23TL & PVI 28TL Installation and Operation Manual
13.2 Input DC (PV) Specifications
Absolute Maximum Input Voltage
Maximum PV Power
Operating Input Voltage
Strike (Startup Voltage/Power)
MPPT Input Voltage Range
MPPT Trackers
Maximum Operating Input Current
Maximum Short Circuit Current
13.3 Other Specifications
Integrated String
Combiner Option
Operational Ambient
Temperature
Storage Temperature
dBA (Decibel) Rating
Operating Altitude
Inverter Enclosure
Safety Listings &
Certifications
Certification Agency
Weight
BTU Rating
DOCR‐070365‐E
PVI23TL
15.5 per MPPT
(31)
480‐800
2 with 4‐Fused Inputs per Zone
25 per MPPT
(50)
41 per MPPT
(82)
Table 13.3 – DC Input Specifications
8 String Inputs , 12‐15 A (4 per MPPT)
‐13°
to 140°F (‐25° to 60°C) Derating occurs above 45°C
‐22°
13123ft/400m (derating from 6562ft/2000m)
UL 1741/IEEE 1547, IEEE 1547.1, UL 1699B
CSA C22.2#107.1, FCC part 15 B
Table 13.4 – Other Specifications
PVI 28TL
1000
19 per MPPT
(38)
300‐900
330VDC/300W
500‐800
29 per MPPT
(58)
48 per MPPT
(96)
to 158°F (‐30° to 70°C)
< 55dBA @ 3m
Type 4
CSA
132lbs (55kg)
1911BTU/Hr
PVI Series Inverters
Units
VDC
kW
VDC
VDC
Amps
Amps
Page 50 of 57