The electronic control of the thermal module will automatically
check which zones are connected to the bus.
The menu items of the zone in the electronic control of the ther-
mal module will be available when one or more zone manage-
ment devices are detected.
The electronic control of the thermal module remembers the
zone number detected when a device is connected.
The zone number detected is not automatically removed when
the corresponding accessory is no longer connected.
The zone number needs to be removed manually.
Removing the zone number
− remove the bus connection of the zone to be deleted;
− access the Settings/Zone Config./Zone;
− select the disconnected zone;
− go to Remove Zone;
− press the ► key to highlight the values, change them to
"Yes" with the ▲ / ▼ keys, press the ● key to confirm and
remove the zone from the display menus.
Example:
External Zone
3
"
"
Detection
"
"
Remove Zone
"
"
External Zone
3
"
"
Detection
"
"
Remove Zone
"
"
No
"
"
No
"
"
No
"
"
Yes
"
"
121
MANAGING ADDITIONAL ZONE