Model Specifications

Please note that three versions are to be distinguished:
Standard version
High Performance version (H-version)
High Performance version (H-version) in IP65 version
The H-version is characterized by the following enhanced features amongst others:
The housing face plate is not IR transparent film, but a mechanical, robust silicon
wafer disc specially developed for this application, and characterized by its high
permeability to IR radiation, as well as its resistance to sabotage.
Because of this precise optic greater nominal range compared to standard types can
be achieved.
H versions include a built-in heating mechanism.
Because of this heating, applicability extends to harsh climatic environments. The
detectors can be used in spite of variations in temperature, because the resulting air
condensation, which could cause signal attenuation due to water droplets building up
on the face plate or the mirror, is counteracted.
The following specifiations are valid for all ADPRO PRO-PIR detector models:
SPECIFICATIONS
Spectral response
Speed ranges for detection
Sensitivity adjustments
(% per default setting)
Window
Vandalism detection of housing
Alarm indication
Alarm outputs
Communication
Temperature compensation
Supply voltage
Current consumption
Power consumption of heater
Operating temperature
Doc. 20780_03
Planning and Commissioning Manual
All ADPRO PRO-PIR Detectors
8-14μm, double filter
0,2 – 5,0 m/s
DIP-
: 40%, 75% 100%
switch
Sensitivity or Range, depending on model, see section 16.1
and 16.2.
PRO
: 20 - 140%
software
depending on models:
all single-sensor detectors (18, 30, 40, 45): 20-140%
all multi-sensor detectors (51, 85, 100, 250): 50-150%
Standard version
:
High-Performance
:
H-versions
Tilt and housing opening detection (NC contact 30V/100 mA)
Internal LED
PRO-xxx
1x relais SPST 30V
@ 100 mA max.
DC
1x open collector 30V
@ 50 mA max.
DC
PRO-250H
1x relais SPST 30VDC @ 100 mA max.
1x open-collektor 30VDC @ 50 mA max.
3x optocoupler outputs for one each alarm zone
(short/medium/long)
RS-485, 9,6kBit/s
Full compensation over the whole operating temperat. range
10,5 - 30V
, 24V
±15% (w/o heater)
DC
AC
18 mA @ 12V
, 14 mA @ 24V
DC
2W / 176 mA @ 12 V
and -40°C (H-versions only)
DC
Standard versions
PE-Filter, IR transmissive
Silicon wafer
DC
: -20º up to +60°C