ADPRO Passive-Infrared (PIR) PRO Series by Xtralis
5.4.1.2 Planning
Because of these circumstances a curtain detector should be used; depending on the size of
the area the following detectors might be considered:
PRO-40
PRO-45, PRO-45H, PRO-45D, PRO-45DH
PRO-51
PRO-85, PRO-85H
PRO-100, PRO-100H
PRO-250H
In this case, a very narrow PRO-45 was chosen.
5.4.2 Monitoring of an enclosure with particularly careful
monitoring of the corners
5.4.2.1 Requirements
Monitoring of all four sides of a medium-high fence, with barbed wire around the top, on the
inside. Particular attention is paid to the corner areas, because the bases of the poles can be
easily mounted, and thus gives an incentive to climb over. The interior remains largely
unmonitored. Each alarm from a detector leads to an alarm or a camera circuit.
5.4.2.2 Planning
Doc. 20780_03
NOTE!
Creep zones are monitored by precedent detectors.
Over-length is avoided by using the existing fence.