Download Print this page

Programming A New Master Code - CDVI CAASE Installation Manual

Back-lit keys keypad 100 user codes - flush mount

Advertisement

Edition 06/2006
II. PROGRAMMING
A. Erase Keypad Memory / Reset Keypad to Factory Default Values
1. Enter the master code twice (12345 default value master code).
2 beeps are emitted to confirm entry in programming mode.
2. Press A6. The green LED lights on during 1 second. Press on A
A6
lights on solid green. Wait until the green LED lights off. The reset is then completed when the red
LED lights on and then lights off.
The keypad exits from programming mode and the default values are restored.
OR
1.
Cut the power off the keypad. Put P2 jumper.
2. Power the keypad. The green LED lights on. Wait a few seconds, one beep is emitted. The green
LED's lights off. Remove P2 jumper.
3. The keypad is set to the default values.
B. Programming the Code Length
1. Enter the master code twice (12345 default value master code). The red LED lights on to confirm
entry in programming mode.
2. Press A4 to program the code length. The green LED lights on during 1 second. Press 4 for a 4-
digit code, press 5 for a 5-digit code or press 6 for a 6-digit code. The green LED lights on for 1
second to confirm the new code length.
A4
3. Press A5 to program the master code. The green LED lights on during 1 second. Enter the 4, 5 or
6-digit new master code. The green LED lights on during 1 second to confirm the new master
code.
4. Press B to exit from programming mode. The red LED lights off to confirm that the keypad is in
stand-by operating mode.
Red LED flashing time indicates a data computing error.
Master code or user code: 12369
Changing to a 4-digit code: Enter 2369
Set the code length first and then program the new master code.
C. Programming a New Master Code
1. Enter the master code twice (12345 default value master code). The red LED lights on to confirm
entry in programming mode.
A5
2. Press A5 to program the master code. The green LED lights on during 1 second. Enter the 4, 5 or
6-digit new master code. The green LED lights on during 1 second to confirm the new master
code.
3. Press B to exit from programming mode. The red LED lights off to confirm that the keypad is in
stand-by operating mode.
and
B to start the reset. The LED
P2
Master code or user code: 12369
Changing to a 6-digit code: Enter 012369
3

Advertisement

loading