Download Print this page

CDVI CAASE Installation Manual page 6

Back-lit keys keypad 100 user codes - flush mount

Advertisement

Edition 06/2006
H. Programming a Sub Master Code
1. Enter the master code twice (12345 default value master code).The red LED's light on to confirm
entry in programming mode.
2. Press A7 to enter in sub master code menu of group 1. The green LED lights on during 1 second.
A7
Enter the new sub master code. The green LED lights on during 1 second to confirm
programming of the new sub master code.
3. Press A8 to enter in sub master code menu of group 2. The green LED lights on during 1 second.
A8
Enter the new sub master code. The green LED lights on during 1 second to confirm
programming of the new sub master code.
4. Press A9 to enter in sub master code menu of group 3. The green LED lights on during 1 second.
A9
Enter the new sub master code. The green LED lights on during 1 second to confirm
programming of the new sub master code.
5. Press B to exit from programming. The red LED's light off to confirm exit from programming.
I. . Enable/Disable Audible Feedback
The audible feedback is always enabled in programming mode or when the relay is energized.
To ENABLE the audible feedback at the press of any key:
1. Enter the master code twice (12345 default value master code).
The red LED's light on to confirm entry in programming mode.
AA
2. Press AA. One beep is emitted. Enter 1 to ENABLE the audible feedback at the press of any
digit key, 1 beep is emitted to confirm the new set up.
To DISABLE the audible feedback at the press of any key:
3. Press AA. One beep is emitted. Enter 0 to DISABLE the audible feedback at the press of any
digit key, 1 beep is emitted to confirm the new set up.
Press B to exit from programming. 2 beeps are emitted.