E. Programmation des temporisations
1. Enter the master code twice (12345 default value master code). The red LED lights on to confirm
entry in programming mode.
2. Press A0 to program the key-in keypad time and the backlit keys time. The green LED's light
A0
during 1 second. Enter the time in second – 10 for 10 seconds up to 99 for 99 seconds. For
permanent backlit enter 00. The green LED lights on during 1 second to confirm the time
validation.
3. Press A1 to program the time relay output 1. The green LED lights on during 1 second.
A1
Enter the time in seconds – 01 for 1 second up to 99 for 99 seconds. Enter 00 for a toggled
output. The green LED lights on during 1 second to validate the time programmed.
4. Press A2 to program the time relay output 2. The green LED lights on during 1 second.
A2
Enter the time in seconds – 01 for 1 second up to 99 for 99 seconds. Enter 00 for a toggled
output. The green LED lights on during 1 second to validate the time programmed.
5. Press A3 to program the time relay output 3. The green LED lights on during 1 second.
A3
Enter the time in seconds – 01 for 1 second up to 99 for 99 seconds. Enter 00 for a toggled
output. The green LED lights on during 1 second to validate the time programmed.
6. Press B to exit from programming mode. The red LED lights off to confirm that the keypad is in
stand-by operating mode.
Red LED flashing 4 times indicates a data computing error.
F. Reset Master Code to Factory Default Value
Place the jumper on P2 in the back of the keypad. The green LED's light on and one beep is emitted.
Wait for the green LED's to light off. Remove jumper from P2. The master code is reset to default
setting 123456 in 6-digit code, 12345 in 5-digit code or 1234 in 4-digit code.
G. . Enable/Disable user code modification by user
The Sub Master code allows the user to change its own code without having to enter in
programming mode. For security reasons the code need to be changed periodically. This feature
makes it easier and faster for the user to change its user code.
Place the jumper on P3 to enable user to reprogram its own user code.
Remove the jumper from P3 to disable the user to reprogram its own code.
1.
Enter the old user code. The relay is activated and the green LED lights on.
2.
Enter immediately the 2-digit sub master code (A and B Factory Default Value).
The red LED lights on.
3.
Enter the new user code. The green LED lights on during 1 second, the new user code is
programmed. The red LED lights off.
4.
Enter the new user code to verify.