Refrigerant Leakage Detection Diagnosis And Solution - Pioneer CB009GMFILCFHD Service Manual

3d dc inverter heat pump
Table of Contents

Advertisement

16.3.5 Refrigerant Leakage Detection diagnosis and solution (EC)
Error Code
Malfunction decision
conditions
Supposed causes
Trouble shooting:
Power off, then restart the
unit 2 minutes later.
Yes
Check cool air blowing out
from indoor air outlet
No
Check leakage of system
No
check blockIng of system and
clear the blocking
EC
Define the evaporator coil temp.T2 of the compressor just starts
running as Tcool.
In the beginning 5 minutes after the compressor starts up, if T2
<Tcool-2℃ does not keep continuous 4 seconds and this
situation happens 3 times, the display area will show "EC" and
AC will turn off.
T2 sensor faulty
Indoor PCB faulty
System problems, such as leakage or blocking.
Yes
Yes
94
Check if T2 sensor
Yes
Replace indoor PCB.
Repair the leakage and
recharge the refrigerant.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents