16.1 Indoor Unit Error Display

Operation
Timer lamp
lamp
☆ 1 time
☆ 2 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 8 times
☆ 1 time
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 8 times
☆ 9 times
☆ 10 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 8 times
Display
LED STATUS
X
E0
Indoor unit EEPROM parameter error
Communication malfunction between indoor and
X
E1
outdoor units
X
E3
Indoor fan speed has been out of control
X
E4
Indoor room temperature sensor (T1 ) malfunction
X
E5
Evaporator coil temperature sensor (T2) malfunction
X
EC
Refrigerant leakage detection
X
EE
Water-level alarm malfunction
O
F0
Current overload protection
O
F1
Outdoor ambient temperature sensor (T4 ) malfunction
O
F2
Condenser coil temperature sensor (T3) malfunction
Compressor discharge temperature sensor (T5)
O
F3
malfunction
O
F4
Outdoor unit EEPROM parameter error
O
F5
Outdoor fan speed has been out of control
Indoor coil outlet pipe sensor(Located on outdoor unit
O
F6
low pressure valve)
Communication malfunction between Cassette optional
O
F7
lift panel and the unit
O
F8
Cassette optional lift panel malfunction
O
F9
Cassette optional lift panel not closed
P0
Inverter module (IPM) malfunction
P1
Over-voltage or under-voltage protection
P2
Compressor top high temperature protection (OLP)
P3
Low ambient temperature cut off in heating
P4
Compressor drive malfunction
P5
Indoor units mode conflict
P6
Low pressure protection
P7
Outdoor IPM temperature sensor error
O(light)
X(off)
☆(flash)