Over Voltage Or Too Low Voltage Protection Diagnosis And Solution - Pioneer CB009GMFILCFHD Service Manual

3d dc inverter heat pump
Table of Contents

Advertisement

16.3.8 Over voltage or too low voltage protection diagnosis and solution (P1)
Error Code
Malfunction
decision
conditions
Supposed causes
Trouble shooting:
Check the power supply
Yes
Check the connections and
wires
Yes
Check the voltage between P
and N
Yes
Check the reactor
Yes
Replace the reactor
P1
An abnormal voltage rise or drop is detected by checking the
specified voltage detection circuit.
Power supply problems.
System leakage or block
PCB faulty
No
No
No
No
99
Stop the unit
Correct the connections or
replace the wires.
Replace the IPM board
Replace outdoor main PCB
Remark:
Measure the DC voltage
between P and N port.
The normal value should
be around 310V.