Pioneer CB009GMFILCFHD Service Manual page 84

3d dc inverter heat pump
Table of Contents

Advertisement

When the AC enter into the information enquiry status, it will display the code value in the next 25s , the
details are as follows.
Enquiry
Display value
information
T1,T2,T3,T4,
-1F,-1E,-1d,-1c,-
T2B,TP,TH,
1b,-1A
Targeted
-19—99
Frequency,
A0,A1,...A9
Actual
b0,b1,...b9
Frequency
c0,c1,...c9
d0,d1,...d9
E0,E1,...E9
F0,F1,...F9
Indoor fan
0
speed
1,2,3,4
/Outdoor fan
speed
14-FF
EXV opening
0-FF
angle
Compressor
0-FF
continuous
running time
Causes of
0-99
compressor
stop.
Reserve
0-FF
Meaning
-25,-24,-23,-22,-21,-2
0
-19—99
100,101,...109
110,111,...119
120,121,...129
130,131,...139
140,141,...149
150,151,...159
OFF
Low speed, Medium
speed, High speed,
Turbo
Actual fan
speed=Display value
turns to decimal
value and then
multiply 10. The unit
is RPM.
Actual EXV opening
value=Display value
turns to decimal
value and then
multiply 2.
0-255 minutes
For the detailed
meaning, please
consult with engineer
81
Remark
1. All the displaying temperature is actual
value.
2. All the temperature is °C no matter
what kind of remote controller is used.
3. T1,T2,T3,T4,T2B display range:-25~70,
TP display range:-20~130.
4. Frequency display range: 0~159HZ.
5. If the actual value exceeds the range, it
will display the maximum value or minimum
value.
For some big capacity motors.
For some small capacity motors,
display value is from 14-FF(hexadecimal),
the corresponding fan speed range is from
200-2550RPM.
If the actual value exceeds the
range, it will display the maximum
value or minimum value.
Decimal display