Boiler-stove system for heating combined with a water heater.
This layout is purely indicative. Have a plumber design and install the system.
Boiler-stove system for producing domestic hot water with
assembled KIT 4, combined with a water heater.
This layout is purely indicative. Have a plumber design and install the system.
- 27
-
LEGEND
AF:
Cold Water
AL:
Water supply
C:
Filling/Topping up
CA:
Wall mounted water heater
EV3:
Three-way solenoid valve
NA: Normally Open
NC: Normally Closed
GR:
Filling unit
MI:
Outlet to system
P:
Pump (circulator)
RA:
Radiators
RI:
Inlet from system
S:
Drain
SB:
Water heater
ST:
Temperature Detector
TS:
Boiler-Stove
TC:
Contact thermostat
V:
Ball valve
VA:
Automatic bleed valve
Vec:
Closed Expansion Tank
VR:
Check valve
VSB:
Safety pressure valve Internal
stove components Manifold
LEGEND
ACS:
Domestic Hot Water
AF:
Cold Water
AL:
Water supply
C:
Filling/Topping up
CA:
Wall mounted water heater
EV :
Three-way solenoid valve
NA: Normally Open
NC: Normally Closed
F:
Flow switch
GR:
Filling unit
MI:
Outlet to system
P:
Pump (circulator)
PS:
Detector housing
RA:
Radiators
RE:
Electronic regulator
RI:
Inlet from system
S:
Drain
AC:
Plate heat exchanger
ST:
Temperature Detector
TS:
Boiler-Stove
V:
Ball valve
Vec:
Closed Expansion Tank
VR:
Check valve
VSP:
Safety pressure valve