Deif SGC 110 User Manual page 24

Single genset controller
Table of Contents

Advertisement

Level 2
Disconnect on Oil Pressure Switch
(DISCONN ON LLOP SW)
Pressure Switch Transient Time
(LLOP SW TRANS TIME)
Crank Disconnect At Alt Frequency
(ALT FREQUENCY)
Crank Disconnect At Engine Speed
(ENGINE SPEED)
Disconnect On Charging Alt Voltage
(DISC ON CHG ALT VOLT)
Charging Alt Disconnect Volt Threshold
(CHG ALT THRESHOLD)
Table 6.14
Speed Monitoring (SPEED MONITOR)
Level 2
Engine Speed Sense Source
(SPEED SENSE SOURCE)
Flywheel Teeth (Magnetic Pickup)
W-Point Frequency@ 1500
Under-speed Shutdown
(UNDER SPEED SHUTDOWN)
Under-speed Threshold
(UNDER SPEED THRESH)
Under-speed Delay
(UNDER SPEED DELAY)
Over-speed Threshold
(OVER SPEED THRESH)
Over-speed Delay
(OVER SPEED DELAY)
Gross Over-speed Threshold
(GROSS OS THRESHOLD)
Table 6.15
Battery Monitoring (BATTERY MONITOR)
Level 2
Low Battery Voltage Action
(LOW VOLT ACTION)
Low Battery Voltage Threshold
(LOW VOLT THRESHOLD)
Low Battery Voltage Delay
(LOW VOLT DELAY)
High Battery Voltage Action
(HIGH VOLT ACTION)
USER MANUAL 4189341228A UK
Range
Enable
Disable
0.0 to 3.0 s
10 to 70 Hz
150 to 4000 RPM
Enable
Disable
5.0 to 30.0 V
Range
Alternator frequency
N/A
N/A
Enable
Disable
0 to 3600 RPM
1 to 60 s
700 to 4000 RPM
1 to 20 s
100 to 200 %
Range
None
Notification
Warning
Electrical Trip
Shutdown
8.0 to 31.0 V
5 to 1800 s
None
Notification
Warning
Electrical Trip
Page 24 of 34