Configuration; Buttons Function Information In Setting - TBB Energier Apollo CH2.0M User Manual

All in one inverter
Table of Contents

Advertisement

6. Configuration

Settings may only be changed by a qualified engineer. Carefully read the
instructions before changes are made.
On delivery, Energier Apollo is set to standard factory values. In general, these settings are
suitable for power backup mode. User can use LCD interface or through Rapconfig software to
setup Energier Apollo system configuration. For LCD interface see section 5.4 operation detail
status: LCD indications.
Possibly, the standard battery charging voltage is not suitable for your
batteries! Refer to the manufacturer's documentation, or consult your
battery supplier!
After press and hold "ESC" buttons for 1 second, Energier Apollo will return to main menu from any
sub-menu page.
Press "page down" and "page up" button to switch between the items, then press "enter" button.
Status
Information
Alarm
Setting
Note: the password is "1234"

6.1 Buttons function information in setting

Button
Password
Enter
* * * *
ESC
Enter
Description of function
1)Return to previous menu; 2) Cancel current setting
1)Page up; 2)Select setting value or optional
1)Page down; 2)Select setting value or optional
1)Confirm the selected item; 2)Confirm current setting
Energier Apollo User Manual
Enter
35
General
Advanced

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents