Connection Of Pv Cabling - TBB Energier Apollo CH2.0M User Manual

All in one inverter
Table of Contents

Advertisement

4.6 Connection of PV cabling

PV input terminal connector can be found on the bottom of Energier Apollo, see section 3.2 wiring
area description. PV cable cross section sees following table, if the input PV supply is rated at a
lower value, the PV cable cross section should be down sized accordingly.
Model No.
CH2.0M
CH2.0S
CH3.0S
CH4.0S
It can only provide one way of PV panel connection but through additional PV box or MC4 multi-in-
one connector, multiple strings of PV panels can be connected with Energier Apollo.
Please ensure PV panel voltage matches the model you install, the wrong PV panel
voltage can destroy equipment and it is out of warranty.
Please double confirm polarity of PV input. And ensure PV max current does not
exceed rated PV charging value.
Maximum torque of PV terminals: 2Nm
Recommended PV panel
Recommended
Model No.
CH2.0M
CH2.0S
CH3.0S
CH4.0S
Please ensure the PV array used in each system operates within the MPPT operational windows.
Following table shows effects of different PV array voltage.
PV Wiring (10m)
10mm
10mm
2
10mm
2
10mm
2
Max PV Open
PV(Vmpp)
circuit voltage(Voc)
32-95
64-140
64-140
64-140
Maximum torque of PV terminals
Rated PV
charging current
100
60
150
60
150
60
150
60
22
Energier Apollo User Manual
2Nm
2Nm
2Nm
2Nm
Recommended
PV(W)
2000
4000
4000
4000

Hide quick links:

Advertisement