9. Technical data

Model No.
LCD display
AC in MCB
AC out MCB
INVERTER
Nominal battery voltage (VDC)
Nominal input voltage Range (VDC)
Cont. power @25℃ (VA)
Power 30mins @25℃ (W)
Cont. power @25℃ (W)
Cont. power @40℃ (W)
Output voltage
Total harmonic distortion
Efficiency (max)
Zero load power (W)
Zero load power (PS mode) (W)
AC input
range (VAC)
Weak grid & GEN
Typical transfer time
Transfer switch (A)
Shortcut protection
CH2.0M
D40
C16
24
~
18
2000
2000
1800
1600
93%
14
3.5
UPS mode
CH2.0S
D40
C16
34
2000
2000
1800
1600
230VAC ± 2%, 220~240VAC settable,
50Hz ± 0.05%, 50/60Hz settable
14
3.5
184
168
< 20ms (typical 10ms)
Auto disconnect
51
Energier Apollo User Manual
CH3.0S
yes
D40
C25
48
~
40
62.8
3000
3000
2700
2400
<3%
96%
17
4.5
~
264
~
276
31
CH4.0S
D40
C32
4000
4000
3600
3200
20
5