Table of Contents Safety Instructions Model Identification and how to order Definition and terminology Mounting and Installation Wiring Troubleshooting Specification Specifications Dimensions No.PS※※-OME0004-H...
Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Safety Instructions Caution We develop, design, and manufacture our products to be used for automatic control equipment, and provide them for peaceful use in manufacturing industries. Use in non-manufacturing industries is not covered. Products we manufacture and sell cannot be used for the purpose of transactions or certification specified in the Measurement Act.
Page 5
Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
Page 6
Caution ■After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty. Disconnect the power supply and stop the fluid supply.
Page 7
●Product handling Installation •Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws and brackets may be broken. If the tightening torque is insufficient, the product can be displaced and loosen the mounting screws. •Be sure to ground terminal FG when using a commercially available switch-mode power supply. •Do not drop, hit or apply shock to the Pressure Sensor.
Page 8
Environment •Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result. •Do not use in a place where the product could be splashed by oil or chemicals. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires).
Model Indication and how to order ○Option Description Part number Remarks Connector for pressure sensor controller ZS-28-C 1 pc. per set Sensor cable ZS-26-F Cable length: 3 m Cable length: 3 m Connector for pressure sensor controller + ZS-26-J The connector is not connected to Sensor cable the cable at the time of shipment ■Definition and terminology...
Mounting and Installation ■Wiring ○Attaching the connector to the lead wire •Sensor wire is stripped as shown in the right figure. •Do not cut the insulation. •The core of the corresponding color shown in the following table is put into the pin of the number stamped on the connector for sensor connection to the back.
Page 11
○Connector and applicable pressure sensor Connecting/Disconnecting •When connecting the connector, insert it straight onto the pin holding the lever and connector body between fingers and lock the connector by pushing the lever claw into the square groove in the housing until connector clicks.
Troubleshooting ○Cross-reference for troubleshooting Problem Possible cause Investigation method Countermeasure Check if the analog output line is connected Incorrect wiring Correct the wiring. with a load. (1) Check if the proper load is connected. Non-compliance (2) Check if input impedance of input Connect a proper load.
Specification ■Specifications Model No. PSE530 PSE531 PSE532 PSE533 Rated pressure range 0 to 1 MPa 0 to -101 kPa 0 to 101 kPa -101 to 101 kPa Extension analog output range -0.1 to 0 MPa 10.1 to 0 kPa -10.1 to 0 kPa Withstand pressure 1.5 MPa 500 kPa...
○Analog output Range Rated pressure range For vacuum 0 to -101 kPa -101 kPa 10.1 kPa For compound -101 to 101 kPa -101 kPa 101 kPa For low pressure 0 to 101 kPa 101 kPa -10.1 kPa For positive pressure -0 to 1 MPa 1 MPa -0.1 MPa...
Need help?
Do you have a question about the PSE53 Series and is the answer not in the manual?
Questions and answers