Mitel MX-ONE Installation Instruction page 29

Table of Contents

Advertisement

I
B
NSTALLING
OARDS AND
29
C
ABLING
Connector row
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Table 9
Synchronization ring front connector TX configuration. (X13)
A
1
Ring TX comm+
2
ACDM RX+
3
Ring TX comm-
4
ACDM RX-
5
Ring TX sync+
6
Ring TX sync-
Note: If the Sync cable is prolonged, the Twisted pair configuration and polarity has to
be kept. See Figure 21: Sync ring cable design (TSR9011226) on page 30
Table 10 Synchronization ring front connector RX configuration. (X12)
A
1
Ring RX comm-
2
ACDM TX+
3
Ring RX comm+
4
ACDM TX-
5
Ring RX sync+
6
Ring RX sync-
A
EPB6 (red)
EPA6 (green)
EPB4 (red)
EPA4 (blue)
Not used
EPB1 (white)
EPA1 (orange) EPB2 (green)
LB15 (yellow)
LA15 (brown)
LB13 (yellow)
LA13 (orange) LB14 (green)
LB11 (black)
LA11 (brown)
Not used
Not used
LB7 (red)
LA7 (brown)
LB5 (red)
LA5 (orange)
LB3 (white)
LA3 (brown)
LB1 (white)
LA1 (orange)
Not used
B
Bus comm+
Not used
Buss comm-
Not used
Bus sync+
Bus sync-
B
Bus comm+
Not used
Buss comm-
Not used
Bus sync+
Bus sync-
B
C
Not used
EPB7 (brown) EPA7(red)
EPB5 (orange) EPA5 (red)
EPB3 (brown) EPA3 (white)
EPB0 (blue)
LB12 (blue)
LB10 (green)
LB9 (orange)
LB8 (blue)
LB6 (green)
LB4 (blue)
LB2 (green)
LB0 (blue)
C
Bus 0 Volt
ACDM TX+
Bus TX-strap
ACDM TX-
Ring 0 Volt
Ring TX-strap
C
Bus RX-strap
ACDM RX+
Bus o Volt
ACDM RX-
Ring RX-STRAP
Ring 0 Volt
21/1531-ASP11301 Uen C 2017-03-28
D
EPA2 (white)
EPA0 (white)
LA14 (yellow)
LA12 (yellow)
LA10 (black)
LA9 (black)
LA8 (black)
LA6 (red)
LA4 (red)
LA2 (white)
LA0 (white)
D
Not used
D
Not used