EMC Connectrix B Series Hardware Reference Manual page 40

Hide thumbs Also See for Connectrix B Series:
Table of Contents

Advertisement

Operating the DS-5300B
Table 2
LED name
Power Supply
Status
Fan Status
40
EMC Connectrix B Series DS-5300B Hardware Reference Manual
Nonport Side LED Patterns During Normal Operation
LED color
Status of hardware
No light
Power supply is not receiving power
or is off.
Steady green
Power supply is operating normally.
Steady amber (for
Power supply fault for one of the
more than 5 seconds)
following reasons:
Power supply is switched off
The power cable is disconnected
The power supply has failed
No light
Fan assembly is not receiving
power.
Steady green
Fan assembly is operating normally. No action required.
Steady amber (for
Fan fault for one of the following
more than 5 seconds)
reasons:
One or more of the fan(s) in the fan
assembly has failed
The fan FRU was disabled by the
user
Note: When the switch is first
powered on the fan status LED will
show amber until POST has
completed.
Note: When the switch is
first powered on the
power supply status
LED will show amber
until POST has
completed.
Recomended action
Verify that the power supply is on and
seated and the power cord is connected to
a functioning power source.
No action required.
Try the following:
Check the power cable connection
Verify that the power supply is powered on
Replace the power supply FRU
Try the following:
Verify that the fan FRU is seated correctly
Verify that the switch is powered on
Try the following:
Verify that the fan FRU is enabled (use the
fanEnable command)
Replace the fan FRU