2.2. Operating modes / Parameters

Press the function key "arrow right" or "arrow left" (3 or 4) to select the parameters. Only the
parameter designation which is flashing on the display can be set by means of the function keys (1 or
2).
.
Overview – Operating modes / Parameters
MODE
MCTIME
OP
PRE
LIFT
GAS
Explanation of operating modes:
OP
Operating state
The operating mode "OP" allows normal welding operation with the welding parameters set.
PRE
Preweld current test
The adjustment "PRE" enables you to test performance using the set parameters without application
of main current and serves to control the adjustment of the welding gun.
LIFT
Lift test
This operating mode enables you to adjust or check the lift of the welding gun.
GAS
Gas test
This operating mode checks whether shielding gas flows through the gas shroud of the welding gun.
As long as the push button is pressed, shielding gas flows out of the gas shroud on the welding gun.
PCTIME
1
2
UP TO
1000
GPTIME
40
60
UP TO
1000