Hang The Device In Place - Berbel Smartline BKH 80 ST Operating And Installation Instructions For The Models

Headroom hood
Hide thumbs Also See for Smartline BKH 80 ST:
Table of Contents

Advertisement

Installation
3.4.4

Hang the device in place

The device is designed to be hung on walls.
When mounting on a solid wall:
☞ Make sure that the wall has sufficient load bearing
capacity.
☞ Use the fastening materials provided.
With different installation situations:
☞ Enquire about alternative fastening systems (e.g. consult
with your architect).
☞ Only use fastening hardware suitable for the type of wall.
245
=
Safety distance (x):
y Recommendation 450 mm.
y With electric hobs, at least 450 mm.
y With gas hobs, at least 650 mm.
Distances from the centre point of the socket opening on the
device rear:
y Top 105 mm from the left fastening point.
y Side 245 mm from the hood centre axis.
☞ Determine the hanging position.
☞ Make sure that the safety distance is complied with.
10
600
=
D WARNING
Risk of death due to explosions or electric shock!
Drilling through gas, water or electrical lines can lead to
hazardous situations.
☞ Ensure that there are no lines in the wall at the fastening
points.
☞ Determine the locations of the fastening points and mark
them.
☞ Drill the holes in the wall.
☞ Insert the wall plugs into the holes.
a
The fastening screws are only tightened once the device has
been aligned.
☞ Tighten the mounting screws appropriately.
Ø 8
a
a = 7
6005045_0 – 05.12.2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartline bkh 80 st permalytSmartline bkh 90 stSmartline bkh 90 st permalyt

Table of Contents