Summary of Contents for Berbel Blockline BWH 60 BL
Page 1
Wall hood Blockline Operating and installation instructions for the models BWH 60 BL BWH 90 BL BWH 120 BL 6005077_a...
Page 2
Document information Symbol clarification - text ☞ Handling requirement Operating and installation instructions for: y BWH 60 BL E02 wall hood y Listing y BWH 90 BL E02 wall hood y BWH 120 BL E02 wall hood D Reference to another point in this document Descriptions are identical for all models.
Safety information Safety information General safety instructions D WARNING! Proper intended use Hazard through a disregard of the operating and installation instructions! The device serves to extract cooking vapours. This manual contains important information for the safe The device is intended exclusively for private domestic use. handling of the device.
Product information Product information Operating modes The device is suitable for the following operating modes: y Recirculated air mode Functional principle y Extracted air mode y Hybrid mode 2.2.1 Recirculated air mode The filter filling in the recirculated air filter neutralises any smelly odours present.
Product information Product overview Scope of delivery A Chimney B Hood body C Upper section with bulging edge (removable) D Capillar Trap (removable) E Lower section (removable) F Ratings plate (in the air induction shaft of the Capillar Trap) G Control panel H Hob lighting A Hood body B Chimney (two-part, can be pulled apart)
Product information Technical data 230 V / 230 V / 230 V / Connection voltage 50 Hz 50 Hz 50 Hz Total power 177 W 177 W 181 W Fan power consumption 170 W 170 W 170 W Lighting 6.9 W, 6.9 W, 10.9 W, 306 lx...
Installation Installation Requirements for the installation location D WARNING! Safety instructions for installation Risk of death due to improper installation! Disregard of the ambient conditions can lead to hazardous situations, e.g. in the handling of electrical power or gas. D WARNING! ☞...
Installation Requirements for individual operating modes Requirements for the exhaust air ducting (only for extracted air mode or hybrid mode) Further accessories may be required depending on the operating mode. D WARNING! Fire hazard and asphyxiation hazard due to improper 3.3.1 Requirements for recirculated air mode installation! When using the exhaust air ducting with other devices y Recirculated air filter at the fan outlet.
Installation Installation procedure 3.5.2 Unpack the device Short overview: D ATTENTION! 1. Preparation for installation 2. Unpack the device Hazard of glass breaking or other damage due to 3. Removing the lower section, bulging edge and Capillar Trap incorrect handling! 4.
Installation 3.5.3 Removing the lower section, bulging edge and The bulging edge is attached and held in the device by Capillar Trap magnets. D ATTENTION! Danger of property damage through falling parts! When working on the device, parts of the device or tools could fall and damage the kitchen equipment.
Installation D WARNING 3.5.4 Hang the device in place Risk of death due to explosions or electric shock! The device is designed to be hung on walls. The chimney can Drilling through gas, water or electrical lines can lead to be adapted to the ceiling height by pulling it out.
Page 13
Installation a = 7 b = 3-6 The top fastening screws should only be tightened once the device has been aligned. The lower fastening screws prevent the device pulling away ☞ Hang the device on the mounting points. from the wall and are no longer accessible after the device is hung in place.
Installation 3.5.5 Connect accessories Wall box y The wall box is closed when the control contacts are Depending on the installation situation, available accessories open. may be connected to the hood, e.g.: y The wall box is open when the control contacts are y Wall box closed.
Installation 3.5.6 Install filter (with recirculating and hybrid 3.5.7 Connect exhaust air ducting (with exhausted operation) air and hybrid operation) There is a pipe connection (Ø 150 mm) on the fan housing as Extracted air mode an installation aid for the installation of the filter. The filter is placed correctly when the bottom edge of the filter is parallel to the top edge of the fan‘s housing and the gap is approximately 3 mm wide.
Installation 3.5.8 Establish electrical power supply ☞ Observe the voltage specifications on the ratings plate. ☞ Lift the chimney up with two persons. ☞ Place the lower edge of the chimney into the groove of the device. ☞ Pivot the chimney flush against the wall. ☞...
Installation 3.5.10 Insert the Capillar Trap, bulging edge and lower section After the installation, the parts lying inside should be re-fitted. ☞ Pivot the lower section upwards until both magnetic fasteners can be heard to click into place. 3.5.11 Check and carry out commissioning ☞...
Operation Operation Measures to ensure a sufficient supply of fresh air: ☞ Open the windows. ☞ Open the doors. ☞ Ensure that the window contact switch and the wall box Safety instructions for operation are installed and ready for operation. ☞...
Operation Operating the device 4.2.1 Normal operation The device is operated from the control panel. D WARNING Fire hazard due to grease residue! In operation grease residue, which is highly inflammable, collects in and on the device. ☞ Clean the device properly. D “5.
Operation 4.2.2 Extraction mode / recirculated air mode 4.2.4 Window contact switch changeover If a window contact switch is connected to the device, this If the device is configured for hybrid mode, it is possible to monitors whether the corresponding window is open or switch between extraction mode and recirculated air mode closed.
Operation 4.2.6 Run-on function 4.2.7 AutoRun The device comes with a run-on function. When the function Devices equipped with the AutoRun module start is used, the device continues to work 10 minutes after being automatically when the cooktop is turned on. When the switched off.
Operation Configuring the device Button Function Automatic run-on. Button Function As delivered, the function is turned on. The device is turned on. ☞ Touch the button one time. ☞ Touch and hold 1x button for longer than Button glows brightly: 5 seconds until the configuration steps are Automatic run-on is activated.
Cleaning Cleaning Cleaning procedures The device draws in dirt particles (e.g. grease and oil particles) with the air from the room. The dirt particles are separated Safety information for cleaning and collected in the upper section, on the bulging edge, in the lower section and in the Capillar Trap.
Page 24
Cleaning Lower Section The lower section is held in the device by two pins at the sides. ☞ Pull the bulging edge from the upper section. ☞ Clean the upper section with a soft, moist cloth. ☞ Clean the bulging edge. ☞...
Maintenance Maintenance 6.2.2 Replacing filter filling (with recirculating and hybrid mode) Odours are trapped in the filter filling in the recirculating air Safety instructions for maintenance filter or hybrid filter. The odour-free, cleaned room air is fed back into the room. D WARNING! Recirculating air filters and hybrid filters are maintenance-free Hazard through a disregard of the maintenance...
Page 26
Maintenance Removing the hybrid filter ☞ Slide the inner chimney duct downwards. ☞ Remove the exhaust pipe from the hybrid filter. ☞ Lift the filter at least 30 mm. ☞ Remove the filter to the front. The replacement of the filter filling is carried out as described in the associated instructions.
Maintenance Fault rectification Moisture in the device. y Dripping or splashing water has penetrated the device. Possible faults are described below: y Liquid (e.g. from vases, bottles on the device) has Description of the fault. penetrated the device. y Possible cause. ☞...
Dismounting Dismounting D WARNING! Danger of injuries through improper handling! Taking the device down requires a great deal of physical exertion due to its size and weight. If the device falls down, serious injuries are possible. ☞ Two persons are required to take the device down. ☞...
Disposal Disposal Dispose of the device D ATTENTION! Dispose of packaging Risk of environmental damage due to improper disposal of the device! D ATTENTION! The device is subject to the European Directive 2012/19/EU and should not be disposed of with household waste. Risk of environmental damage due to improper disposal ☞...
Annex Contact If you have any questions or suggestions, please select from the following options: Post: berbel Ablufttechnik GmbH Sandkampstraße 100 D-48432 Rheine Tel: +49 (0) 5971 80 80 9 - 0 Mon to Thu 08:00 – 17:30 hrs and Fri 08:00 – 16:30 hrs...
Need help?
Do you have a question about the Blockline BWH 60 BL and is the answer not in the manual?
Questions and answers