User Protection
3CX Auto Provision
Advanced Settings
Validate Hostname in
Certificate
Enable SIP Notify
Authentication
Factory reset
Maintenance → System Diagnosis
Syslog
Syslog Protocol
Syslog Server
Syslog Level
to Yes, device will download and apply (overwrite) all available configs in the
same order.
When user protection is on, pvalues that user sets will not be changed by
provision or provider.
Phone will multicast SUBSCRIBE for provision if this feature is enabled.
To validate the hostname in the SSL certificate
Device will challenge NOTIFY with 401 when set to Yes
Press Start to begin Factory Reset of the phone.
If set to SSL/TLS, the syslog messages will be sent through secured TLS
protocol to syslog server.
Default setting is "UDP".
Note: The CA certificate is required to connect with the TLS server.
The URL or IP address of the syslog server for the phone to send syslog to.
Note: By adding port number to the Syslog server field (i.e.,
172.18.1.1:1000), the phone will send syslog to the corresponding port of
that IP.
Selects the level of logging for syslog.
The default setting is "None". There are 4 levels: DEBUG, INFO, WARNING
and ERROR.
Syslog messages are sent based on the following events:
Product model/version on boot up (INFO level).
NAT related info (INFO level).
sent or received SIP message (DEBUG level).
SIP message summary (INFO level).
inbound and outbound calls (INFO level).
registration status change (INFO level).
negotiated codec (INFO level).
Ethernet link up (INFO level).
SLIC chip exception (WARNING and ERROR levels).