Parameter list (by parameter number)

2

PARAMETER

2.1
Parameter list (by parameter number)
The following parameters are dedicated to CC-Link IE TSN communication. Set the parameters according to application. For
other parameters, refer to the Instruction Manual (Detailed) of the FR-A800 inverter.
Pr.
Pr.
group
79
D000
Operation mode selection
340
D001
Communication startup mode selection
342
N001
Communication EEPROM write selection
Communication reset selection/Ready bit
status selection/Reset selection when
inverter errors cleared
N010
Communication reset selection
349
N240
Ready bit status selection
Reset selection when inverter errors
N241
cleared
434
N700
IP address 1
435
N701
IP address 2
436
N702
IP address 3
437
N703
IP address 4
438
N710
Subnet mask 1
439
N711
Subnet mask 2
440
N712
Subnet mask 3
441
N713
Subnet mask 4
Stop mode selection at communication
502
N013
error
541
N100
Frequency command sign selection
Operation frequency during communication
779
N014
error
804
D400
Torque command source selection
810
H700
Torque limit input method selection
1130
N741
Link speed selection
1442
N760
IP filter address 1 (Ethernet)
1443
N761
IP filter address 2 (Ethernet)
1444
N762
IP filter address 3 (Ethernet)
1445
N763
IP filter address 4 (Ethernet)
IP filter address 2 range specification
1446
N764
(Ethernet)
IP filter address 3 range specification
1447
N765
(Ethernet)
IP filter address 4 range specification
1448
N766
(Ethernet)
1459
N746
Clock source selection

The initial value after all parameters have been cleared.
12
PARAMETER
Name
0 to 4, 6, 7
0 to 2, 10, 12
0, 1
0, 1, 100, 101, 1000,
1001, 1100, 1101
0, 1
0, 1
0, 1
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 4, 11, 12
0, 1
0 to 590 Hz, 9999
0 to 6
0 to 2
0, 1
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255, 9999
0 to 255, 9999
0 to 255, 9999
0 to 2
Minimum
Setting range
setting
increments
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0.01 Hz
1
1
1
1
1
1
1
1
1
1
1
Refer
Initial
Customer
to
value
setting
page
0
19
0
19
0
14
0
14
0
14
0
14
0
14
0 (192
)
20

0 (168
)
20

0 (50
)
20

0 (2
)
20

0 (255
)
20

0 (255
)
20

0 (255
)
20

0 (255
)
20

0
14
0
24
9999
14
0
24
0
24
0
20
0
20
0
20
0
20
0
20
9999
20
9999
20
9999
20
0
24