Procedure 2: Cleaning With Solvents By The Dipping Or The Spraying Method; Reason For The Job; Job Set-Up Information; Job Set-Up - Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List

Table of Contents

Advertisement

TASK 21-22-91-100-806-A01
6.

Procedure 2: Cleaning with Solvents by the Dipping or the Spraying Method

A.

Reason for the Job

WARNING: USE SOLVENTS WHICH HAVE A FLASH POINT OF MORE THAN 50 °C TO 55 °C
WARNING: DO NOT USE ANY CHLORINATED SOLVENT. CHLORINATED SOLVENTS ARE
WARNING: – DO NOT BREATHE THE FUMES. THE SOLVENTS ARE DANGEROUS.
CAUTION:
Self-explanatory
B.

Job Set-up Information

(1)
Consumable materials
CODE
REFERENCE
M49A
70030 CARECLEAN AS1
(a)
C. Job Set-up
WARNING: – THE SOLVENTS ARE DANGEROUS FOR YOUR HEALTH, AND CAN CAUSE
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
(122 °F TO 131 °F) IN SPECIFIED STABLE CONDITIONS.
NOT APPROVED.
– USE EYE PROTECTION. DO NOT LET THE SOLVENTS TOUCH YOUR SKIN.
– CLEAN THE PARTS IN A ROOM WHERE AIRFLOW IS SUFFICIENT.
– DO NOT CLEAN NEAR AN OPEN FLAME.
– CAREFULLY OBEY THE CLEANING PROCEDURES, OR REPLACE THEM WITH
A PROCEDURE WHICH IS SPECIFIED BY THE MANUFACTURER IF YOU USE
EQUIVALENT PRODUCTS.
– AFTER YOU COMPLETE THE PROCEDURE, YOU MUST PUT PROTECTIVE
CAPS OR APPLICABLE PACKAGING MATERIAL ON THE PARTS.
Example: - Cleaning material (M49A).
DAMAGE TO PARTS IF THEY DETERIORATE BECAUSE OF: POLLUTION,
WATER, GREASE, METAL PARTICLES, TEMPERATURE.
– THE SOLVENTS MUST THUS BE PERFECTLY CLEAN AND YOU MUST REPLACE
THEM FREQUENTLY. THE CONTAINERS MUST BE FREE FROM UNWANTED
PARTICLES, FOR THE DIPPING AND THE SPRAYING OPERATIONS.
00001059
DESIGNATION
CLEANING MATERIAL
21-22-91
Page 4007
Dec 15/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

00001059 amdt b00001059 amdt c

Table of Contents