D. Procedure
WARNING: – DO NOT BREATHE THE FUMES. THE SOLVENTS ARE DANGEROUS.
– CLEAN THE PARTS IN A CORRECTLY VENTILATED ROOM.
– DO NOT CLEAN NEAR AN OPEN FLAME OR AN INCANDESCENT MATERIAL.
– USE THE SOLVENT BETWEEN 10 °C AND 15 °C (50 °F TO 59°F), WHICH IS LESS
THAN THE FLASH POINT.
SUBTASK 21-22-91-110-001-A01
(1)
Cleaning with Solvents
(a)
Put the part momentarily in the solvent , or apply the solvent to the part as a spray. If
necessary, complete the cleaning with a soft brush, or with a soft piece of material
(such as wood or plastic).
(b)
At the end of the full cleaning operation, put the part momentarily in clean solvent, or
apply clean solvent to the part as a spray.
(c)
Dry the parts with clean and dry compressed air that is clean and dry (free from dust
and grease).
E.

Close-up

Not applicable