Job Set-Up; Procedure - Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List

Table of Contents

Advertisement

(d)
Energy Sources
DESIGNATION
28 VDC SUPPLY
(2)
Referenced Information
REFERENCE
GRAPHIC-21-22-91-991-004-A01
GRAPHIC-21-22-91-991-005-A01
GRAPHIC-21-22-91-991-006-A01
GRAPHIC-21-22-91-991-007-A01
GRAPHIC-21-22-91-991-008-A01
C. Job Set-up
Not applicable
D. Procedure
SUBTASK 21-22-91-750-001-A01
(1)
Insulation Resistance Test
(Ref. Fig. 1001)
(a)
Connect the fan to the test lead (T01).
(b)
Connect together the test lead (T01) pins.
(c)
Set the ON/OFF switch of the test lead (T01) to ON.
(d)
Set the HIGH/LOW switch of the test lead (T01) to HIGH.
(e)
With the megohmmeter measure the insulation resistance under 50 VDC, between the
test lead (T01) pins together and the bonding stand off.
(f)
Keep this voltage during 1 min.
(g)
Make sure that the value is more than or equal to 10 MΩ.
(h)
Disconnect the test lead (T01) from the fan.
SUBTASK 21-22-91-750-002-A01
(2)
ON/OFF Command Test
(Ref. Fig. 1002)
(a)
Attach the fan on the test bench (T02).
(b)
Connect the fan to the test lead (T01).
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
QTY
CHARACTERISTICS
1
SODILEC TYPE SDR/TH 60 V 65 A OR
EQUIVALENT
PAGE
BLOCK
1000
1000
1000
1000
1000
DESIGNATION
FIGURE 1001
FIGURE 1002
FIGURE 1003
FIGURE 1004
FIGURE 1005
21-22-91
Page 1002
Dec 15/06