Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List page 118

Table of Contents

Advertisement

APPLICABLE PAGES: A1 TO A2
PNR:00001059
TEST BY:
LAST INSPECTION APPROVAL BY:
CMM POS.
(Ref.
TESTING
Para.1.D (1) SUBTASK
21-22-91-750-003-A01)
(Ref.
TESTING
Para.1.D (1) SUBTASK
21-22-91-750-004-A01)
(Ref.
TESTING
Para.1.D (1) SUBTASK
21-22-91-750-005-A01)
(Ref.
TESTING
Para.1.D (1) SUBTASK
21-22-91-750-006-A01)
(Ref.
TESTING
Para.1.D (1) SUBTASK
21-22-91-720-001-A01)
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
00001059
MEASUREMENT
High Speed & Low Speed Selection Test under 28 VDC
Power switch : ON
Speed selection switch : LOW
Speed selection switch : HIGH
Start-up Current Test under 28 VDC
Power switch : ON
Input current at start up
PERFORMANCES TESTS
Free Delivery Test at Low Speed under 28 VDC
Power switch : ON
Speed selection switch : LOW
Rotation speed (RS)
Free Delivery Test at High Speed under 28 VDC
Power switch : ON
Speed selection switch : HIGH
Rotation speed (RS)
Operational Test at Low Speed
Power switch : ON
Speed selection switch : LOW
FILE No:
S/N
DATE:
DATE:
NOMINAL VALUE
TOLERANCE
The fan operates at
low speed
The fan operates at
high speed
< 40 A during the first
1,2 s
8000 rpm ≤ RS ≤
8600 rpm
7,5 A ≤ I ≤ 10,5 A
Input current (I)
12500 rpm ≤ RS ≤
13100 rpm
≤ 32 A
Input current
Pressure
> 800 Pa at 120 l/s
≤ 28 A (stabilized)
Input current
21-22-91
ACTUAL
ACTUAL
VALUE A
VALUE B
APPENDIX A
Page A-2
Dec 15/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

00001059 amdt b00001059 amdt c

Table of Contents