Honeywell LMB HYPER 120-03 Component Maintenance Manual With Illustrated Parts List page 95

Table of Contents

Advertisement

(h)
(i)
(j)
(k)
(l)
(m)
CAUTION: FOR PNR 00001059 AMDT C, MAKE SURE THAT THE DRAINAGE HOLE OF
(n)
(o)
(p)
(q)
(r)
(s)
(t)
The document reference is online, please check the correspondence between the online documentation and the printed version.
COMPONENT MAINTENANCE MANUAL
5
Attach the power board (01-370) to the drain (01-430B) with three screws (01-380),
six screws (01-390), fifteen washers (01-400) and six nuts (01-410).
6
Torque the screws (01-380) and (01-390) to the specified value (Ref. TASK
21-22-91-820-802-A01).
Shrink three 20 mm (0.787 in) lengths of heat shrinkable conduit (01-770) on these wires:
– The two stator probe white wires,
– The yellow and the black wires of the detection board,
– The orange and the red wires of the detection board.
Shrink three 25 mm (0.984 in) lengths of heat shrinkable conduit (01-780) on each pair
of stator phases wires grouped by color.
Group all the wires in three bundles and shrink three 35 mm (1.378 in) lengths of heat
shrinkable conduit (01-760).
Put the five detection board wires and the two stator probe wires together in a 50 mm
(1.97 in) length of heat shrinkable conduit (01-760).
Put the six stator wires together by pairs and by colors in three 35 mm (1.378 in) lengths
of heat shrinkable conduit (01-760).
Put all the wires through the power board (01-370) by their related holes.
THE DRAIN (01-430B) IS LOCATED AT THE BOTTOM.
Put the drain/power board assembly in position in the equipped housing (01-640).
NOTE: Pull the wires which go to the filter board through the dedicated hole of the
equipped housing (01-640).
Install a 80 mm (3.15 in) length of conduit (01-270) on the wires which go to the filter
board and push it in the power module.
Apply a layer of adhesive material (M38B) on the thread of the screw (01-220).
Attach the cover (01-210) on the grommet (01-240) with the screw (01-220) and the
washer (01-230).
Torque the screw (01-220) to the specified value (Ref. TASK 21-22-91-820-802-A01).
Shrink three 15 mm (0.590 in) lengths of heat shrinkable conduit (01-760) on each pair of
stator wires and push them in the holes.
NOTE: Let between 2 and 3 mm (0.0787 to 0.1181 in) of heat shrinkable conduit
(01-760) over the power board (01-370).
Carefully pull all the wires through the holes.
00001059
21-22-91
Page 7009
Dec 15/06