4 INSTALLATION
NOTE!
The power source can be connected for generator power. For more information,
contact authorised ESAB service personnel.
Check that the unit is connected to the correct mains power supply voltage, and that it is
protected by the correct fuse size. A protective earth connection must be made, in
accordance with regulations.
A.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
Mains voltage
Mains cable area
Phase current I
Uin 380 V
eff
Fuse anti-surge
Fuse CMCB-surge
Phase current I
Uin 400 V
eff
Fuse anti-surge
Fuse CMCB-surge
Phase current I
Uin 440 V
eff
Fuse anti-surge
Fuse CMCB-surge
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with
Swedish regulations. Use the power source in accordance with the relevant
national regulations.
0463 283 001
Mig 4004i A44
380-440 V, +/- 10%, 3~50/60 Hz
4G4 mm
- 12 -
2
22 A
25 A
32 A
19 A
20 A
32 A
18 A
20 A
32 A