Section 8
PROBLEM
1. No product being
dispensed.
2. Unit will not operate in the
"AUTO" or "WASH" mode.
3. No compressor operation
in the "AUTO" mode.
Model 390 Tim Hortons

Troubleshooting Guide

PROBABLE CAUSE
a. Power switch is in the
"OFF" position.
b. Improper mixing of
product.
c. Inadequate mix in hopper.
d. Product frozen-up in
freezing cylinder.
e. Unit out on reset.
f. Beater assembly is not
rotating at all or is rotating
counterclockwise. Control
switch is not in "AUTO".
g. Unit unplugged at wall
receptacle.
h. Tripped circuit breaker or
blown fuse.
a. Unit unplugged at wall
receptacle.
b. Tripped circuit breaker or
blown fuse.
c. Unit out on reset.
a. Beater motor is out on
overload.
b. Condenser dirty A/C.
c. The "CLEANING REQ'D"
light is lit.
23
REMEDY
a. Place power switch in the
"AUTO" position.
b. Carefully follow directions
for mixing product.
c. Fill hopper with mix.
d. Contact a service
technician.
e. Place power switch in the
"OFF" position. Press the
reset button. Return
control switch to "AUTO".
f. The power switch must be
in "AUTO". If beater is
rotating counterclockwise,
call service technician to
correct rotation.
g. Plug in power cord.
h. Reset circuit breaker or
replace fuse.
a. Plug in power cord.
b. Reset circuit breaker or
replace fuse.
c. Place the power switch in
the "OFF" position. Press
the reset button. Return
control switch to "AUTO".
a. Place control switch in
"OFF" position. Press the
reset button. Return
control switch to "AUTO".
b. Clean condenser monthly.
c. Clean the unit according
to instructions in the
Operator's Manual.
Troubleshooting Guide
PAGE
REF.
18
- - -
18
- - -
11
1
- - -
- - -
- - -
- - -
11
11
21
19

Hide quick links: