Taylor Tim Hortons 390 Original Operating Instructions page 11

Slush freezer
Hide thumbs Also See for Tim Hortons 390:
Table of Contents

Advertisement

DO NOT allow untrained personnel to
operate this machine.
DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
DO NOT remove any internal operating
parts (example: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
DO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
This machine must be placed on a level
surface. Extreme care should be taken in moving it
for any reason. Two or more persons are required to
safely move this machine. Failure to comply may
result in personal injury or equipment damage.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
Model 390 Tim Hortons
Cleaning and sanitizing schedules are
governed by your Federal, State, or local regulatory
agencies and must be followed accordingly. Please
refer to the cleaning section of this manual for the
proper procedure to clean this unit.
This machine is designed to maintain
product temperature under 41° F (5° C). Any product
being added to this machine must be below 41° F
(5° C). Failure to follow this instruction may result in
health hazards and poor freezer performance.
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3" (76 mm) on
the left side, 0" on the rear and right side, with 12"
(305 mm) to the ceiling when the top air discharge is
installed.
If the top air discharge is not installed, the required
clearance is 6" (152 mm) on each side and 0" at the
rear.
Minimum air clearances must be met to assure
adequate air flow for optimum performance.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70 -75 F (21 -24 C). The freezer
has successfully performed in high ambient
temperatures of 104 (40 C) at reduced capacities.
DO NOT run the machine without product. Failure to
follow this instruction can result in damage to the
machine.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.