Carrier Frequency Error; Bit Error Rate; Table 18: Transmitter Ber Specifications With Quasonix Demodulator - Quasonix TIMTER QSX-V Series Installation And Operation Manual

Multi-mode digital telemetry transmitter
Table of Contents

Advertisement

Band ID
Band
Code
Y
L and C
Z
Lower L and
Euro Mid C

6.5 Carrier Frequency Error

The frequency error is less than ±20 ppm over all combinations of temperature, voltage, and aging (up to five years).

6.6 Bit Error Rate

The transmitter meets the following BER limits when tested with the Quasonix' multi-mode, multi-symbol trellis
demodulator.

Table 18: Transmitter BER Specifications with Quasonix Demodulator

BER
10-3
10-4
10-5
10-6
81
Quasonix, Inc.
TIMTER™ Multi-mode Digital Telemetry Transmitter
Minimum
Freq
1435.5 MHz
1750.0 MHz
and
4400.0 MHz
5091.0 MHz
1435.5 MHz
and
5150.0 MHz
Maximum Eb/N0 (dB)
PCM/FM, Tier 0
SOQPSK-TG, Tier I
7.0
8.5
9.5
10.5
Maximum
Default Freq
Freq
1534.5 MHz
1450.5 MHz
1855.0 MHz
and
4950.0 MHz
5150.0 MHz
1534.5 MHz
1450.5 MHz
and
5250.0 MHz
MULTI-h CPM, Tier II
9.0
11.0
12.5
14.0
Tuning
Max
Steps
Power
0.5 MHz
18 W
0.5 MHz
20 W
11.8
13.3
14.3
15.3