Mnemonic
Name
Command
AC
Automatic
Carrier Output
AFMS
Analog FM
AI
Aux Input Select
35
Quasonix, Inc.
TIMTER™ Multi-mode Digital Telemetry Transmitter
Description
Report or set automatic carrier
output state
With automatic carrier ON (AC 1),
the unit will output an
unmodulated, on-frequency
carrier if there is no clock present.
When automatic carrier is OFF
(AC 0), the RF output will be
muted in the absence of clock.
Note that the AI, CF, and CS
commands can create a clock,
even when one is not externally
applied.
Examples:
AC
Report the automatic
carrier state
AC 0
Set automatic carrier
OFF
AC 1
Set automatic carrier ON
Refer to section 4.2.1.1.1 for
related AC command detail
Set analog FM mode
Examples:
AFMS 1.0
Set analog FM
deviation in units of MHz per volt
Enable, disable, or show the
current state of the auxiliary input
With the auxiliary input active, the
unit automatically switches to
clock-free operation (CF 0).
Examples:
AI
Report the current value
of AI
AI 1
Enable the aux input
AI 0
Disable the aux input
Option (s)
Setting
Required
Saved?
AC
N
ACS
Y
FM
Y
AI
Y
Factory
Default
AC 1
AFMS 0
AI 0